Informações sobre este manual
Projeto de pesquisa: Informações sobre este manual. Pesquise 861.000+ trabalhos acadêmicosPor: Patrickwesley • 19/5/2014 • Projeto de pesquisa • 1.015 Palavras (5 Páginas) • 622 Visualizações
. General information
1.1 Information on this operating manual
This operating manual is part of the technical documentation for the AGRAMKOW safety tester EST900/S. This operating manual contains all the information on how to operate this device properly, safely and economically, how to prevent dangerous situations, how to reduce repair costs and downtimes, and how to prolong the service life of these devices. Should you, while perusing this operating manual, find any misprints, any information you do not understand, or which is incorrect, please do not hesitate to inform AGRAMKOW.
Pictographs and symbols Warnings are characterised by warning triangles with danger symbol, warning of danger which can lead to personal injury and/or material damage:
General warning
Danger caused by electric current or voltage Information is characterised by the information pictograph, providing advice or additional information:
This is information text
EST900/S
No-Ver: 146-400000A Rev. 1.0 Date: 07-01-2009 Page 6 of 64
2. System menu: setting of system parameters
2.1 General information
In the area of system parameters important basic settings on all functions of the EST900/S are defined. On the following pages you will find explanations on the options of all system parameters. To guarantee correct and safe test operation, the “System parameters” area should be made absolutely inaccessible to unauthorised persons by use of a password. Please observe the information on the application of the password in 2.8.
2.2 Setting of language
With this parameter you can change the system language of the operating panel. After having selected a language with the handwheel all screen dialogues, when acknowledged by means of pressure on the handwheel, will be switched immediately to the new language. The available languages are: German English French Spain Italian Dutch Polish Czech Danish Portuguese
2.3 Setting of operating mode
In the same way, you can switch between the different operating modes of the device: Manual
Regular, manual test operation with single tests or with test programmes Digital
Test programme selection and start/stop functions are performed in digital test operation via digital interface X6 (“ext. I/O”) (see 5.2). Bar code
In bar code operation the tester is controlled by a bar code scanner via interface X5 (USB). The bar code from the scanner selects the test programme (see 5.1). PLIS
In PLIS operation the device is integrated into a local network (LAN) and the test programmes and results are administered by a central server (see 5.3).
2.3.1 Operating mode “Manual”
If you select operating mode “Manual”, a dialogue screen will appear on which further options for this operating mode can be defined:
EST900/S
No-Ver: 146-400000A Rev. 1.0 Date: 07-01-2009 Page 7 of 64
Activate
If an operating mode other than “Manual” was set before then this option must be selected to activate the operating mode “Manual”. Digital output
If “Digital output” is activated (default option) then all eight inputs and all eight outputs of digital I/O interface X6 are available for test step “I/O test”.
If “Digital output” is not activated then outputs 1–4 of I/O interface are used for hardware status signals. For test step “I/O test” only outputs 5–8 (and all of the inputs) will be available (see 3.3.14, and annex A-4).
2.3.2 Operating mode “Digital”
Even after selecting operating mode “Digital” a dialogue screen will appear with further options: Activate
If an operating mode other than “Digital” was set before then this option has to be selected to activate operating mode “Digital”. Acknowledgement
With this option you can select how to perform an ERROR test in digital operation. If “Acknowledgement” has not been activated the next test will be started immediately by a start signal EXT_START on X6. If “Acknowledgement” has been activated then an erroneous test has to be acknowledged first via EXT_ACK before the next test can be started via EXT_START.
Information: If “Acknowledgement” for the digital mode is activated then the acknowledgement of a FAIL/ERROR test result will also be requested in
...